New
Gamesa Electric
Proteus PCS-E Stations

Energy Storage
Solutions

Maximum efficiency and compactness for utility scale energy storage projects

Gamesa Electric Proteus PCS Stations

Gamesa Electric
Proteus PCS-E Stations

Plug & Play MV Solutions

better

Better LCoS

Compact design that achieves a high power density obtaining overall cost reduction by using less PCS Station units per project.

Design with best-in-class components that guarentees less probability of failure and therefore less operation cost (materials and workforce).

Market leading PCS-E efficiency of 99.45%.

reduction

High safety with minimum CAPEX

Safety embedded in the design through direct communication with the associated battery system.

Less units needed per project, which results in lower equipment cost.

Reduced costs of transportation, offloading and site preparation.

puzzle

Flexibility

Wide range of configurations with outputs from 2550 to 9400 kVA and IEC & UL certifications.

Double power module topology for two independent battery connections per PCS-E allowing for much lower DC shot-circuit currents and increased system availability.

Battery agnostic design to accommodate different battery technologies, including: li-ion, lead-acid, flow and others.

link

Plug & play

Fully assembled and tested MV solution.

Quick installation in field, reducing installation time and costs.

Easy to support and mantain.

2 inverters

IEC version
2 x PCS-E

1 inverters

IEC version
1 x PCS-E

UL version

UL version
1 x PCS-E

Configurations

Available to fit any customers' needs

The Gamesa Electric Proteus PCS-E Stations
combine maximum power with large
flexibility for best LCoS

HIGH POWER

Gamesa Electric Proteus PCS-E Station
1 x Proteus PCS 4000E 1 x Proteus PCS 4180E 1 x Proteus PCS 4360E 1 x Proteus PCS 4600E 1 x Proteus PCS 4910E 1 x Proteus PCS 5100E
DC Connection
DC Minimum Voltage(1) 934 V 976 V 1018 V 1075 V 1146 V 1202 V
DC Maximum Voltage 1473 V 1500 V 1500 V 1500 V 1500 V 1500 V
Number of Independent Power Modules 2, not galvanically isolated
Max. DC Current @40ºC [104ºF] 2 x 2227 A
Number of Fused DC Inputs(2) Up to 3+ & 3- / 6+ & 6-
Max. DC short-circuit withstanding capability 2 x 250kA, 3ms Double DC bus configuration
1 x 250kA, 3ms Single DC bus configuration
AC Connection
Number of Phases Three-phase
Nominal AC Power Total @25ºC [77ºF]Max. Vdc 4250 kVA 4446 kVA 4639 kVA 4897 kVA 5219 kVA 5477 kVA
Nominal AC Power Total @40ºC [104ºF]Max. Vdc 4000 kVA 4183 kVA 4365 kVA 4607 kVA 4910 kVA 5153 kVA
Nominal AC Power Total @40ºC [104ºF]@1300VDC 4298 kVA 4494 kVA 4689 kVA 4950 kVA 5275 kVA 5535 kVA
Nominal AC Voltage, LV side(2) 660 Vrms 690 Vrms 720 Vrms 760 Vrms 810 Vrms 850 Vrms
Nominal AC Voltage, MV side(2)
Nominal Voltage Allowance Range(2) +/-10%
Frequency Range(2) 46.5 - 53 / 57 - 63.5 Hz
THD of AC Current < 1% @Sn
Power Factor Range(3) 0 (lagging) - 1 - 0 (leading)
Protection Devices
DC Connection Motorized disconnectors, Overvoltage protection (Type 1 + 2 SPD), Reverse polarity detection, DC ground fault and insulation detection, fast fuses (optional)
AC Connection Motorized AC circuit breakers, Overvoltage protection (Type 1 + 2 SPD), Anti-islanding, Voltage failure, Frequency failure, Grid Voltage Fluctuations (LVRT, HVRT)
Over-temperature Protection Included
Emergency Push Button Included
Components Proteus PCS-E Station
PCS-E 1 x Proteus PCS 4000E 1 x Proteus PCS 4180E 1 x Proteus PCS 4360E 1 x Proteus PCS 4600E 1 x Proteus PCS 4910E 1 x Proteus PCS 5100E
Transformer(2)(7) Dy11 KNAN / ONAN
Switchgear(2)(7) 0L1V / 1L1V / 2L1V up to 38 kV
Custom Auxiliary Transformer(2) Optional
Others(2) Auxiliary cabinet
Communications
Control(2) Modbus TCP / IP
Monitoring(2) Modbus TCP / IP
Webserver Included
Other Features
Temperature Range - Operation(4) -20ºC / +60ºC [-4ºF / +140ºF]
Relative Humidity 4% - 100% (without condensation)
Maximum Altitude (without derating)(5) 2,000 m [6561 ft]
Dimensions W x H x D (IEC / UL version)(6) 1,1800 x 2,600 x 2,100 mm / 30 x 8.5 x 8.6 ft
Protection IP54 station / IP55 power converter
Cooling System Liquid & forced air
Optionals Standards/Directives(6)
Low Temperature Kit to up to -30ºC [-22ºF] IEC 62109-1 IEC 62920 IEC 60529 cei 0-16; v2 2021-06 NEC 2020 NEMA 250-2014 Arrete
Factory-fitted DC fuses IEC 62109-2 UL 62109-1 IEC 61727 Allegato A.68-2018 CEA 2019 NFPA 70:2020 UTE C 15-400
Factory-fitted joint DC inputs IEC 61000-6-2/4 IEC 62116 NTS 631 v1.1 SENP, v2.1 SEPE G99 Rule 14, Rule 21 IEEE Std 929-2000 EirGrid V10:2020
Enhanced corrosion protection IEEE 1547 IEC 61683 UL 1741-SB UNE-EN 50541-2-2014 PRC-024-2 IEC 62477-1:2022
Motorized MV Switchgear EN 55011 IEEE 619 CSA C22.2 No 107.1 73/2020 CEC 2015 VDE-AR-N 4110 4120 2018
UPS
Custom Auxiliary Transformer
Measurement of auxiliary consumption
Seismic Reinforcement
Fence for the power transformer

LOW POWER

Gamesa Electric Proteus PCS-E Station
1 x Proteus PCS 2420E 1 x Proteus PCS 2910E 1 x Proteus PCS 3150E 1 x Proteus PCS 3630E 1 x Proteus PCS 3810E
DC Connection
DC Minimum Voltage(1) 566 V 679 V 736 V 849 V 891 V
DC Maximum Voltage 1238 V 1310 V 1347 V 1418 V 1445 V
Number of Independent Power Modules 2, not galvanically isolated
Max. DC Current @40ºC [104ºF] 2 x 2227 A
Number of Fused DC Inputs(2) Up to 3+ & 3- / 6+ & 6-
Max. DC short-circuit withstanding capability 2 x 250kA, 3ms Double DC bus configuration
1 x 250kA, 3ms Single DC bus configuration
AC Connection
Number of Phases Three-phase
Nominal AC Power Total @25ºC [77ºF]Max. Vdc 2577 kVA 3093 kVA 3351 kVA 3866 kVA 4059 kVA
Nominal AC Power Total @40ºC [104ºF]Max. Vdc 2425 kVA 2910 kVA 3152 kVA 3637 kVA 3819 kVA
Nominal AC Power Total @40ºC [104ºF]@1300VDC N/A 3127 kVA 3387 kVA 3908 kVA 4103 kVA
Nominal AC Voltage, LV side(2) 400 Vrms 480 Vrms 520 Vrms 600 Vrms 630 Vrms
Nominal AC Voltage, MV side(2) Up to 34.5kV
Nominal Voltage Allowance Range(2) +/-10%
Frequency Range(2) 46.5 - 53 / 57 - 63.5 Hz
THD of AC Current < 1% @Sn
Power Factor Range(3) 0 (lagging) - 1 - 0 (leading)
Protection Devices
DC Connection Motorized disconnectors, Overvoltage protection (Type 1 + 2 SPD), Reverse polarity detection, DC ground fault and insulation detection, fast fuses (optional)
AC Connection Motorized AC circuit breakers, Overvoltage protection (Type 1 + 2 SPD), Anti-islanding, Voltage failure, Frequency failure, Grid Voltage Fluctuations (LVRT, HVRT)
Over-temperature Protection Included
Emergency Push Button Included
Components Proteus PCS-E Station
PCS-E 1 x Proteus PCS 2420E 1 x Proteus PCS 2910E 1 x Proteus PCS 3150E 1 x Proteus PCS 3630E 1 x Proteus PCS 3810E
Transformer(2)(7) Dy11 KNAN / ONAN
Switchgear(2)(7) 0L1V / 1L1V / 2L1V up to 38 kV
Custom Auxiliary Transformer(2) Optional
Others(2) Auxiliary cabinet
Communications
Control(2) Modbus TCP / IP
Monitoring(2) Modbus TCP / IP
Webserver Included
Other Features
Temperature Range - Operation(4) -20ºC / +60ºC [-4ºF / +140ºF]
Relative Humidity 4% - 100% (without condensation)
Maximum Altitude (without derating)(5) 2,000 m [6561 ft]
Dimensions W x H x D (IEC / UL version)(6) 1,1800 x 2,600 x 2,100 mm / 30 x 8.5 x 8.6 ft
Protection IP54 station / IP55 power converter
Cooling System Liquid & forced air
Optionals Standards/Directives(6)
Low Temperature Kit to up to -30ºC [-22ºF] IEC 62109-1 IEC 62920 IEC 60529 cei 0-16; v2 2021-06 NEC 2020 NEMA 250-2014 Arrete
Factory-fitted DC fuses IEC 62109-2 UL 62109-1 IEC 61727 Allegato A.68-2018 CEA 2019 NFPA 70:2020 UTE C 15-400
Factory-fitted joint DC inputs IEC 61000-6-2/4 IEC 62116 NTS 631 v1.1 SENP, v2.1 SEPE G99 Rule 14, Rule 21 IEEE Std 929-2000 EirGrid V10:2020
Enhanced corrosion protection IEEE 1547 IEC 61683 UL 1741-SB UNE-EN 50541-2-2014 PRC-024-2 IEC 62477-1:2022
Motorized MV Switchgear EN 55011 IEEE 619 CSA C22.2 No 107.1 73/2020 CEC 2015 VDE-AR-N 4110 4120 2018
UPS
Custom Auxiliary Transformer
Measurement of auxiliary consumption
Seismic Reinforcement
Fence for the power transformer

(1)At nominal AC voltage. Consult Gamesa Electric for other options
(2)Consult Gamesa Electric for a especific configuration
(3)Consult P-Q chart
(4)Up to 4,000m [13,123 ft] with derating as optional
(5)UL variant only available for 1-PCS based configuration
(6)Consult Gamesa Electric for other Standards / Directives

HIGH POWER

Gamesa Electric Proteus PCS-E Station
2 x Proteus PCS 4000E 2 x Proteus PCS 4180E 2 x Proteus PCS 4360E 2 x Proteus PCS 4600E 2 x Proteus PCS 4910E 2 x Proteus PCS 5100E
DC Connection
DC Minimum Voltage(1) 934 V 976 V 1018 V 1075 V 1146 V 1202 V
DC Maximum Voltage 1473 V 1500 V 1500 V 1500 V 1500 V 1500 V
Number of Independent Power Modules 2 / 4
Max. DC Current @40ºC [104ºF] 4 x 2500 A
Number of Fused DC Inputs(2) Up to 6+ & 6- / 12+ & 12-
Max. DC short-circuit withstanding capability per PCS 4 x 250kA, 3ms Double bus configuration
2 x 250kA, 3ms Single bus configuration
AC Connection
Number of Phases Three-phase
Nominal AC Power Total @25ºC [77ºF]Max. Vdc 8500 kVA 8892 kVA 9278 kVA 9794 kVA 10438 kVA 10954 kVA
Nominal AC Power Total @40ºC [104ºF]@1300VDC 8000 kVA 8366 kVA 8730 kVA 9214 kVA 9820 kVA 10306 kVA
Nominal AC Power Total @50ºC [122ºF]@1300VDC 8596 kVA 8988 kVA 9378 kVA 9900 kVA 10550 kVA 11070 kVA
Nominal AC Voltage, LV side(2) 2 x 660 Vrms 2 x 690 Vrms 2 x 720 Vrms 2 x 760 Vrms 2 x 810 Vrms 2 x 850 Vrms
Nominal AC Voltage, MV side(2) up to 34.5kV
Nominal Voltage Allowance Range(2) +/-10%
Frequency Range(2) 46.5 - 53 / 56 - 63.5 Hz
THD of AC Current < 1% @Sn
Power Factor Range(3) 0 (lagging) - 1 - 0 (leading)
Protection Devices
DC Connection Motorized disconnectors, Overvoltage protection (Type 1 + 2 SPD), Reverse polarity detection, DC ground fault and insulation detection
AC Connection Motorized AC circuit breakers, Overvoltage protection (Type 1 + 2 SPD), Anti-islanding, Voltage failure, Frequency failure, Grid Voltage Fluctuations (LVRT, HVRT)
Over-temperature Protection Included
Emergency Push Button Included
Components Proteus PCS Station
PCS-E 2 x Proteus PCS 4000E 2 x Proteus PCS 4180E 2 x Proteus PCS 4360E 2 x Proteus PCS 4600E 2 x Proteus PCS 4910E 2 x Proteus PCS 5100E
Transformer(2)(7) Dy11y11 KNAN / ONAN
Switchgear(2)(7) 0L1V / 1L1V / 2L1V up to 36 kV
Custom Auxiliary Transformer(2) Optional
Others(2) Auxiliary cabinet
Communications
Control(2) Modbus TCP / IP
Monitoring(2) Modbus TCP / IP
Webserver Included
Other Features
Temperature Range - Operation(4) -20ºC / +60ºC [-4ºF / +140ºF]
Relative Humidity 4% - 100% (without condensation)
Maximum Altitude (without derating)(5) 2,000 m [6561 ft]
Dimensions W x H x D (IEC / UL version)(5) 11800 x 2600 x 2100 mm / 30 x 8,5 x 8,6 ft
Protection IP54 station / IP55 power converter
Cooling System Liquid & forced air
Optionals Standards/Directives(6)
Low Temperature Kit to up to -30ºC [-22ºF] IEC 62109-1 IEC 62920 IEC 60529 cei 0-16; v2 2021-06 NEC 2020 NEMA 250-2014 Arrete
Factory-fitted DC fuses IEC 62109-2 UL 62109-1 IEC 61727 Allegato A.68-2018 CEA 2019 NFPA 70:2020 UTE C 15-400
Factory-fitted joint DC inputs IEC 61000-6-2/4 IEC 62116 NTS 631 v1.1 SENP, v2.1 SEPE G99 Rule 14, Rule 21 IEEE Std 929-2000 EirGrid V10:2020
Enhanced corrosion protection IEEE 1547 IEC 61683 UL 1741-SB UNE-EN 50541-2-2014 PRC-024-2 IEC 62477-1:2022
Motorized MV Switchgear EN 55011 IEEE 619 CSA C22.2 No 107.1 73/2020 CEC 2015 VDE-AR-N 4110 4120 2018
UPS
Custom Auxiliary Transformer
Measurement of auxiliary consumption
Seismic Reinforcement
Fence for the power transformer

LOW POWER

Gamesa Electric Proteus PCS-E Station
2 x Proteus PCS 2420E 2 x Proteus PCS 2910E 2 x Proteus PCS 3150E 2 x Proteus PCS 3630E 2 x Proteus PCS 3810E
DC Connection
DC Minimum Voltage(1) 566 V 679 V 736 V 849 V 819 V
DC Maximum Voltage 1238 V 1310 V 1347 V 1418 V 1445 V
Number of Independent Power Modules 2 / 4
Max. DC Current @40ºC [104ºF] 4 x 2500 A
Number of Fused DC Inputs(2) Up to 6+ & 6- / 12+ & 12-
Max. DC short-circuit withstanding capability per PCS 4 x 250kA, 3ms Double bus configuration
2 x 250kA, 3ms Single bus configuration
AC Connection
Number of Phases Three-phase
Nominal AC Power Total @25ºC [77ºF]Max. Vdc 5154 kVA 6186 kVA 6702 kVA 7732 kVA 8118 kVA
Nominal AC Power Total @40ºC [104ºF]@1300VDC 4850 kVA 5820 kVA 6304 kVA 7274 kVA 7638 kVA
Nominal AC Power Total @50ºC [122ºF]@1300VDC N/A 6252 kVA 6774 kVA 7816 kVA 8206 kVA
Nominal AC Voltage, LV side(2) 2 x 400 Vrms 2 x 480 Vrms 2 x 520 Vrms 2 x 600 Vrms 2 x 630 Vrms
Nominal AC Voltage, MV side(2) Up to 34.5kV
Nominal Voltage Allowance Range(2) +/-10%
Frequency Range(2) 46.5 - 53 / 56 - 63.5 Hz
THD of AC Current < 1% @Sn
Power Factor Range(3) 0 (lagging) - 1 - 0 (leading)
Protection Devices
DC Connection Motorized disconnectors, Overvoltage protection (Type 1 + 2 SPD), Reverse polarity detection, DC ground fault and insulation detection
AC Connection Motorized AC circuit breakers, Overvoltage protection (Type 1 + 2 SPD), Anti-islanding, Voltage failure, Frequency failure, Grid Voltage Fluctuations (LVRT, HVRT)
Over-temperature Protection Included
Emergency Push Button Included
Components Proteus PCS Station
PCS-E 2 x Proteus PCS 2420E 2 x Proteus PCS 2910E 2 x Proteus PCS 3150E 2 x Proteus PCS 3630E 2 x Proteus PCS 3810E
Transformer(2)(7) Dy11y11 KNAN / ONAN
Switchgear(2)(7) 0L1V / 1L1V / 2L1V up to 36 kV
Custom Auxiliary Transformer(2) Optional
Others(2) Auxiliary cabinet
Communications
Control(2) Modbus TCP / IP
Monitoring(2) Modbus TCP / IP
Webserver Included
Other Features
Temperature Range - Operation(4) -20ºC / +60ºC [-4ºF / +140ºF]
Relative Humidity 4% - 100% (without condensation)
Maximum Altitude (without derating)(5) 2,000 m [6561 ft]
Dimensions W x H x D (IEC / UL version)(5) 11800 x 2600 x 2100 mm / 30 x 8,5 x 8,6 ft
Protection IP54 station / IP55 power converter
Cooling System Liquid & forced air
Optionals Standards/Directives(6)
Low Temperature Kit to up to -30ºC [-22ºF] IEC 62109-1 IEC 62920 IEC 60529 cei 0-16; v2 2021-06 NEC 2020 NEMA 250-2014 Arrete
Factory-fitted DC fuses IEC 62109-2 UL 62109-1 IEC 61727 Allegato A.68-2018 CEA 2019 NFPA 70:2020 UTE C 15-400
Factory-fitted joint DC inputs IEC 61000-6-2/4 IEC 62116 NTS 631 v1.1 SENP, v2.1 SEPE G99 Rule 14, Rule 21 IEEE Std 929-2000 EirGrid V10:2020
Enhanced corrosion protection IEEE 1547 IEC 61683 UL 1741-SB UNE-EN 50541-2-2014 PRC-024-2 IEC 62477-1:2022
Motorized MV Switchgear EN 55011 IEEE 619 CSA C22.2 No 107.1 73/2020 CEC 2015 VDE-AR-N 4110 4120 2018
UPS
Custom Auxiliary Transformer
Measurement of auxiliary consumption
Seismic Reinforcement
Fence for the power transformer

(1)At nominal AC voltage. Consult Gamesa Electric for other options
(2)Consult Gamesa Electric for a especific configuration
(3)Consult P-Q chart
(4)Up to 4,000m [13,123 ft] with derating as optional
(5)UL variant only available for 1-PCS based configuration
(6)Consult Gamesa Electric for other Standards / Directives
(7)UL version: Padmounted Dyn (without external switchgear)

Do you need more information?

Our team is at your disposal

Contact us