New
Gamesa Electric
Proteus PCS Stations

Energy Storage
Solutions

Maximum efficiency and compactness for utility scale energy storage projects

Gamesa Electric Proteus PCS Stations

Gamesa Electric
Proteus PCS Stations

Plug & Play MV Solutions

better

Better LCoS

Compact design that achieves a high power density obtaining overall cost reduction by using less PCS Station units per project.

Design with best-in-class components that guarentees less probability of failure and therefore less operation cost (materials and workforce).

Market leading PCS efficiency of 99.45%.

reduction

High safety with minimum CAPEX

Safety embedded in the design through direct communication with the associated battery system.

Less units needed per project, which results in lower equipment cost.

Reduced costs of transportation, offloading and site preparation.

puzzle

Flexibility

Wide range of configurations with outputs from 2550 to 9400 kVA and IEC & UL certifications.

Double power module topology for two independent battery connections per PCS allowing for much lower DC shot-circuit currents and increased system availability.

Battery agnostic design to accommodate different battery technologies, including: li-ion, lead-acid, flow and others.

link

Plug & play

Fully assembled and tested MV solution.

Quick installation in field, reducing installation time and costs.

Easy to support and mantain.

2 inverters

IEC version
2 x PCS

1 inverters

IEC version
1 x PCS

UL version

UL version
1 x PCS

Configurations

Available to fit any customers' needs

The Gamesa Electric Proteus PCS Stations
combine maximum power with large
flexibility for best LCoS

Gamesa Electric Proteus PCS Station
1 x Proteus PCS 4100 1 x Proteus PCS 4300 1 x Proteus PCS 4500 1 x Proteus PCS 4700
DC Connection
DC Minimum Voltage(1) 849 V 891 V 934 V 976 V
DC Maximum Voltage (w/o Derating) < 1300 V
DC Maximum Voltage (with Derating) < 1500 V
Number of Independent Power Modules per PCS 2
Max. DC Current @40ºC [104ºF] 2 x 2500 A
Number of Fused DC Inputs(2) Up to 6+ & 6-
Max. DC short-circuit withstanding capability 2 x 250kA, 3ms Double bus configuration
1 x 250kA, 3ms Double bus configuration
AC Connection
Number of Phases Three-phase
Nominal AC Power Total @25ºC [77ºF]@1300VDC 4095 kVA 4299 kVA 4504 kVA 4709 kVA
Nominal AC Power Total @40ºC [104ºF]@1300VDC 4095 kVA 4299 kVA 4504 kVA 4709 kVA
Nominal AC Power Total @50ºC [122ºF]@1300VDC 3790 kVA 3979 kVA 4169 kVA 4358 kVA
Nominal AC Voltage, LV side(2) 600 Vrms 630 Vrms 660 Vrms 690 Vrms
Nominal AC Voltage, MV side(2)
Nominal Voltage Allowance Range(2) +/-10%
Frequency Range(2) 47.5 - 53 / 57 - 63 Hz
THD of AC Current < 1% @Sn
Power Factor Range(3) 0 (lagging) - 1 - 0 (leading)
Protection Devices
DC Connection Motorized DC switches (on-load), Overvoltage protection (Type 1 + 2 SPD), Reverse polarity detection, DC ground fault and insulation detection, fast fuses (optional)
AC Connection Motorized AC circuit breakers, Overvoltage protection (Type 1 + 2 SPD), Anti-islanding, Voltage failure, Frequency failure, Grid Voltage Fluctuations (LVRT, HVRT)
Over-temperature Protection Included
Emergency Push Button Included
Components Proteus PCS Station
PCS 1 x Proteus PCS 4100 1 x Proteus PCS 4300 1 x Proteus PCS 4500 1 x Proteus PCS 4700
Transformer(2)(8) Dy11 KNAN / ONAN
Switchgear(2)(8) 0L1V / 1L1V / 2L1V up to 38 kV
Custom Auxiliary Transformer(2) Optional
Others(2) Auxiliary cabinet
Communications
Control(2) Modbus TCP / IP
Monitoring(2) Modbus TCP / IP
Webserver Included
Other Features
Temperature Range - Operation(4) -20ºC / +60ºC [-4ºF / +140ºF]
Relative Humidity 4% - 100% (without condensation)
Maximum Altitude (without derating)(5) 2,000 m [6561 ft]
Dimensions W x H x D (IEC / UL version)(6) 11800 x 2600 x 2100 mm / 30 x 8,5 x 8,6 ft
Protection IP54 station / IP55 power converter
Cooling System Liquid & forced air
Optionals Standards/Directives(6)
Low Temperature Kit to up to -30ºC [-22ºF] IEC 62109-1 IEC 60529
Factory-fitted DC fuses IEC 62109-2 IEC 61727
Factory-fitted joint DC inputs IEC 61000-6-2/4 NTS 631 v1.1 SENP, v2.1 SEPE
Enhanced corrosion protection IEEE 1547 UL 1741-SA
Motorized MV Switchgear EN 55011 CSA C22.2
UPS IEC 62920 NEC 2020
Custom Auxiliary Transformer UL 62109-1 CEA 2007
Seismic Reinforcement IEC 62116 Rule 14, Rule 21
IEC 61683 PRC 024
IEEE 519

(1)At nominal AC voltage. Consult Gamesa Electric for other options
(2)Consult Gamesa Electric for a especific configuration
(3)Consult P-Q chart
(4)With derating from 40ºC [104ºF]
(5)Up to 4,000m [13,123 ft] with derating as optional
(6)UL variant only available for 1-PCS based configuration
(7)Consult Gamesa Electric for other Standards / Directives
(8)UL version: Padmounted Dyn (without external switchgear)

Gamesa Electric Proteus PCS Station
2 x Proteus PCS 4100 2 x Proteus PCS 4300 2 x Proteus PCS 4500 2 x Proteus PCS 4700
DC Connection
DC Minimum Voltage(1) 849 V 891 V 934 V 976 V
DC Maximum Voltage (w/o Derating) < 1300 V
DC Maximum Voltage (with Derating) < 1500 V
Number of Independent Power Modules per PCS / Total 2 / 4
Max. DC Current @40ºC [104ºF] 4 x 2500 A
Number of Fused DC Inputs per PCS / Total(2) Up to 6+ & 6- / 12+ & 12-
Max. DC short-circuit withstanding capability per PCS 4 x 250kA, 3ms Double bus configuration
2 x 250kA, 3ms Double bus configuration
AC Connection
Number of Phases Three-phase
Nominal AC Power Total @25ºC [77ºF]@1300VDC 8190 kVA 8598 kVA 9008 kVA 9418 kVA
Nominal AC Power Total @40ºC [104ºF]@1300VDC 8190 kVA 8598 kVA 9008 kVA 9418 kVA
Nominal AC Power Total @50ºC [122ºF]@1300VDC 7580 kVA 7958 kVA 8338 kVA 8178 kVA
Nominal AC Voltage, LV side(2) 2 x 600 Vrms 2 x 630 Vrms 2 x 660 Vrms 2 x 690 Vrms
Nominal AC Voltage, MV side(2)
Nominal Voltage Allowance Range(2) +/-10%
Frequency Range(2) 47.5 - 53 / 57 - 63 Hz
THD of AC Current < 1% @Sn
Power Factor Range(3) 0 (lagging) - 1 - 0 (leading)
Protection Devices
DC Connection Motorized disconnectors, Overvoltage protection (Type 1 + 2 SPD), Reverse polarity detection, DC ground fault and insulation detection
AC Connection Motorized AC circuit breakers, Overvoltage protection (Type 1 + 2 SPD), Anti-islanding, Voltage failure, Frequency failure, Grid Voltage Fluctuations (LVRT, HVRT)
Over-temperature Protection Included
Emergency Push Button Included
Components Proteus PCS Station
PCS 2 x Proteus PCS 4100 2 x Proteus PCS 4300 2 x Proteus PCS 4500 2 x Proteus PCS 4700
Transformer(2)(8) Dy11 KNAN / ONAN
Switchgear(2)(8) 0L1V / 1L1V / 2L1V up to 36 kV
Custom Auxiliary Transformer(2) Optional
Others(2) Auxiliary cabinet
Communications
Control(2) Modbus TCP / IP
Monitoring(2) Modbus TCP / IP
Webserver Included
Other Features
Temperature Range - Operation(4) -20ºC / +60ºC [-4ºF / +140ºF]
Relative Humidity 4% - 100% (without condensation)
Maximum Altitude (without derating)(5) 2,000 m [6561 ft]
Dimensions W x H x D (IEC / UL version)(5) 11800 x 2600 x 2100 mm / 30 x 8,5 x 8,6 ft
Protection IP54 station / IP55 power converter
Cooling System Liquid & forced air
Optionals Standards/Directives(6)
Low Temperature Kit to up to -30ºC [-22ºF] IEC 62109-1 IEC 60529
Factory-fitted DC fuses IEC 62109-2 IEC 61727
Factory-fitted joint DC inputs IEC 61000-6-2/4 NTS 631 v1.1 SENP, v2.1 SEPE
Enhanced corrosion protection IEEE 1547 UL 1741-SA
Motorized MV Switchgear EN 55011 CSA C22.2
UPS IEC 62920 NEC 2020
Custom Auxiliary Transformer UL 62109-1 CEA 2007
Seismic Reinforcement IEC 62116 Rule 14, Rule 21
IEC 61683 PRC 024
IEEE 519

(1)At nominal AC voltage. Consult Gamesa Electric for other options
(2)Consult Gamesa Electric for a especific configuration
(3)Consult P-Q chart
(4)With derating from 40ºC [104ºF]
(5)Up to 4,000m [13,123 ft] with derating as optional
(6)UL variant only available for 1-PCS based configuration
(7)Consult Gamesa Electric for other Standards / Directives
(8)UL version: Padmounted Dyn (without external switchgear)