New Gamesa Electric Proteus PCS-E Inverter

Maximum efficiency and compactness for utility-scale energy storage projects

Check out

our Solar PV technology and portfolio

Gamesa Electric Proteus PCS-E Battery Inverters

Maximum energy and versatility for utility-scale projects

better

High Round Trip Efficiency (RTE)

High efficiency that allows to improve the overall system RTE and LCoS.

Smart liquid/air cooling system that allows critical components to work at temperature level far below their limits, guaranteeing longer product lifespan and lower thermal losses.

Low power derating, high power capacity at 1500Vdc, wide operating temperature range.

grid

Grid connection

Four quadrant operation for full active and reactive power support to comply with the most demanding grid codes.

Weak grid and micro-grid configuration with a seamless transition and black start capability.

Fast frequency response Synthetic inertia Grid forming in parallel operation with the grid.

thunder

Battery oriented

Safety centered design with instantaneous controls and monitoring.

Double power module topology for two independent battery connections allowing for much lower DC short-circuit currents and increased system availability.

Battery agnostic design to accommodate different battery technologies, up to 1500Vdc, including: li-ion, lead-acid, flow and others.

Coolbrid cooling system

Configurations

Available to fit any customers' needs

GAMESA ELECTRIC PROTEUS PCS 4180EGAMESA ELECTRIC PROTEUS PCS 4360EGAMESA ELECTRIC PROTEUS PCS 4600EGAMESA ELECTRIC PROTEUS PCS 4910E(5)GAMESA ELECTRIC PROTEUS PCS 5150E(5)
DC INPUT
DC Minimum Voltage for grid-tied mode(1)976 V1018 V1075 V1146 V1202 V
DC Maximum Voltage1500 V
Number of Independent Power Modules per PCS2, not galvanically isolated
Max. DC Current2 x 2227 A
Number of Fused DC Inputs per Power Module/Total(2)Up to 3+ & 3- / 6+ & 6-
Max. DC short-circuit withstanding capability2 x 250 kA 3ms Double DC bus configuration
1 x 250 kA 3ms Double DC bus configuration
AC OUTPUT
Number of phasesThree-phase w/o neutral point
Nominal AC Power Total @25ºC [77ºF], 1500VDC4446 kVA4639 kVA4897 kVA5219 kVA5477 kVA
Nominal AC Power Total @40ºC [104ºF], 1500VDC4183 kVA4365 kVA4607 kVA4910 kVA5153 kVA
Nominal AC Power Total @40ºC [104ºF], 1300VDC4494 kVA4689kVA4960 kVA5275 kVA5535 kVA
Nominal AC Voltage(2)690 Vrms720 Vrms760 Vrms810 Vrms850 Vrms
Nominal Voltage Allowance Range(2)+/-15%
Frequency Range(2)46.5 - 53 Hz // 56 - 63.5 Hz
THD of AC Current< 1.0% @Sn
Power Factor Range(3)0 (lagging) - 1 - 0 (leading)
PERFORMANCE
Max. Efficiency98.57%
Stand-by Power Consumption< 200 W
GENERAL DATA
Temperature Range - Operation-20ºC / +60ºC [-4ºF / +140ºF]
Maximum Altitude< 2,000 m [6,561 ft] (w/o derating)
Cooling SystemLiquid & forced air
Relative Humidity4% – 100% (w/o condensation)
Protection ClassIP55 class 1, NEMA3R
Dimensions (W/H/D)4,325 x 2,255 x 1,022 mm [170.3” x 88.8” x 40.2”]
Weight4,535 kg [10,000 lb]
AC PROTECTIONS
AC Side Disconnection & Short-circuit Current ProtectionTwo motorized AC circuit breakers - one per each power module
AC Overvoltage ProtectionType 1 + 2 SPD
Anti-islandingIncluded (SW)
Grid Voltage Fluctuations (LVRT, HVRT)(2)Included (SW)
Frequency FailureIncluded (SW)
DC PROTECTIONS
DC DisconnectionTwo motorized DC switches (on-load) - one per each power module
DC Short-circuit ProtectionDC fast fuses (optional)
DC Over-voltage ProtectionType 1 + 2 SPD
Reverse Polarity DetectionIncluded
DC Ground Fault and Insulation DetectionIncluded
OTHER PROTECTIONS
Over-temperature ProtectionIncluded
Emergency Push ButtonIncluded
COMMUNICATIONS
Control(2)Modbus TCP/IP
Monitoring(2)Modbus TCP/IP
WebserverIncluded
OPTIONALS
Low Temperature Kit to up to -30ºC [-22ºF]
Factory-fitted DC fuses
Factory-fitted joint DC inputs
Enhanced corrosion protection

Standards/Directives(4)

  • IEC 62109-1
  • IEC 62109-2
  • IEC 61000-6-2
  • IEEE 1547
  • EB 55011/CISPR11:2019
  • IEC 62116
  • IEC 61683
  • IEC 60529
  • NTS 631 v1.1 SENP, v2.1 SEPE
  • UL 1741-SB
  • CSA C22.2 No 107.1
  • CEI 0-16; V2 2021-06
  • Allegato A.79
  • ENA G99
  • UNE-EN 50541-2:2014
  • Ambiente e açao climatica 73/2020
  • CEA 2019
  • Rule 14, Rule 21
  • PRC 024-2
  • CEC 2015
  • NEMA 250-2014
  • NFPA 70:2020
  • IEC 62477-1:2022
  • VDE-AR-N 4110 4120 4130 2018
  • Arrêté du 9 juin 2020
  • UTE C15-400
  • EirGrid V10:2020 

(1) At nominal AC voltage. Consult Gamesa Electric for other options
(2) Consult Gamesa Electric for a specific configuration
(3) Consult P-Q chart
(4) Consult Gamesa Electric for more details
(5) Consult Gamesa Electric on the application for this model

GAMESA ELECTRIC PROTEUS PCS 2420EGAMESA ELECTRIC PROTEUS PCS 2910EGAMESA ELECTRIC PROTEUS PCS 3150EGAMESA ELECTRIC PROTEUS PCS 3630EGAMESA ELECTRIC PROTEUS PCS 3810EGAMESA ELECTRIC PROTEUS PCS 4000E
DC INPUT
DC Minimum Voltage for grid-tied mode(1)566 V679 V736 V849 V891 V934 V
DC Maximum Voltage1238 V1310 V1347 V1418 V1445 V1473 V
Number of Independent Power Modules per PCS2, not galvanically isolated
Max. DC Current2 x 2227 A
Number of Fused DC Inputs per Power Module/Total(2)Up to 3+ & 3- / 6+ & 6-
Max. DC short-circuit withstanding capability2 x 250 kA 3ms Double DC bus configuration
1 x 250 kA 3ms Double DC bus configuration
AC OUTPUT
Number of PhasesThree-phase w/o neutral point
Nominal AC Power Total @25°C [77°F], Max. Vdc2577 kVA3093 kVA3351 kVA3866 kVA4059 kVA4250 kVA
Nominal AC Power Total @40ºC [104ºF], Max. Vdc2425 kVA2910 kVA3152 kVA3637 kVA3819 kVA4000 kVA
Nominal AC Power Total @40ºC [104ºF], 1300VDCN/A3126 kVA3387 kVA3908 kVA4103 kVA4298 kVA
Nominal AC Voltage(2)400 Vrms480 Vrms520 Vrms600 Vrms630 Vrms660 Vrms
Nominal Voltage Allowance Range(2)+/-15%
Frequency Range(2)46.5 - 53 Hz // 56 - 63.5 Hz
THD of AC Current< 1.0% @Sn
Power Factor Range(3)0 (lagging) - 1 - 0 (leading)
PERFORMANCE
Max. Efficiency98.57%
Stand-by Power Consumption< 200 W
GENERAL DATA
Temperature Range - Operation-20ºC / +60ºC [-4ºF / +140ºF]
Maximum Altitude< 2,000 m [6,561 ft] (w/o derating)
Cooling SystemLiquid & forced air
Relative Humidity4% – 100% (w/o condensation)
Protection ClassIP55 class 1, NEMA3R
Dimensions (W/H/D)4,325 x 2,255 x 1,022 mm [170.3” x 88.8” x 40.2”]
Weight4,535 kg [10,000 lb]
AC PROTECTIONS
AC Side Disconnection & Short-circuit Current ProtectionTwo motorized AC circuit breakers - one per each power module
AC Overvoltage ProtectionType 1 + 2 SPD
Anti-islandingIncluded (SW)
Grid Voltage Fluctuations (LVRT, HVRT)(2)Included (SW)
Frequency FailureIncluded (SW)
DC PROTECTIONS
DC DisconnectionTwo motorized DC switches (on-load) - one per each power module
DC Short-circuit ProtectionDC fast fuses (optional)
DC Over-voltage ProtectionType 1 + 2 SPD
Reverse Polarity DetectionIncluded
DC Ground Fault and Insulation DetectionIncluded
OTHER PROTECTIONS
Over-temperature ProtectionIncluded
Emergency Push ButtonIncluded
COMMUNICATIONS
Control(2)Modbus TCP/IP
Monitoring(2)Modbus TCP/IP
WebserverIncluded
OPTIONALS
Low Temperature Kit to up to -30ºC [-22ºF]
Factory-fitted DC fuses
Factory-fitted joint DC inputs
Enhanced corrosion protection

Standards/Directives(4)

  • IEC 62109-1
  • IEC 62109-2
  • IEC 61000-6-2
  • IEEE 1547
  • EB 55011/CISPR11:2019
  • IEC 62116
  • IEC 61683
  • IEC 60529
  • NTS 631 v1.1 SENP, v2.1 SEPE
  • UL 1741-SB
  • CSA C22.2 No 107.1
  • CEI 0-16; V2 2021-06
  • Allegato A.79
  • ENA G99
  • UNE-EN 50541-2:2014
  • Ambiente e açao climatica 73/2020
  • CEA 2019
  • Rule 14, Rule 21
  • PRC 024-2
  • CEC 2015
  • NEMA 250-2014
  • NFPA 70:2020
  • IEC 62477-1:2022
  • VDE-AR-N 4110 4120 4130 2018
  • Arrêté du 9 juin 2020
  • UTE C15-400
  • EirGrid V10:2020 

(1) At nominal AC voltage. Consult Gamesa Electric for other options
(2) Consult Gamesa Electric for a specific configuration
(3) Consult P-Q chart
(4) Consult Gamesa Electric for more details

Power Electronics

Motors & Generators

Do you need more information?

Our team is at your disposal