New Gamesa Electric Proteus PV Stations

High-power PV Inverter family

Maximum power with large flexibility for best LCoE

Gamesa Electric Proteus PV Stations

Plug & Play MV Solutions

better

Better LCoE

Compact design that achieves a high power density obtaining overall cost reduction by using less PV station units per project.

Design with best-in-class components that guarantees less probability of failure and therefore less operation cost (materials and workforce).

Market leading inverter efficiency of 99.45%.

reduction

CAPEX reduction

Less units needed per project, which results in lower equipment cost.

Reduced costs of transportation, offloading and site preparation.

Solution delivered preassembled, configured and tested, reducing on-site labour cost.

puzzle

Flexibility

Wide range of configurations with outputs from 3800 to 9400 kVA and IEC & UL certifications.

Bidirectional inverter that allows PV Station to be configured as part of a Battery Energy Storage System (BESS) in DC and AC coupling topologies.

Customization at PV station subsystems, such as MV transformer, auxiliaries’ system and DC input configuration, according to customer necessities.

link

Plug & play

Fully assembled and tested MV solution.

Quick installation on field, reducing installation time and costs.

Easy to support and mantain.

Successfully operating in extreme environments

IEC version

2 Inverters

IEC version

1 Inverter

UL version

1 Inverter

GAMESA ELECTRIC PROTEUS PV STATION1 x Proteus PV 41001 x Proteus PV 43001 x Proteus PV 45001 x Proteus PV 4700
DC CONNECTION
DC Voltage Range835 V - 1500 V875 V - 1500 V915 V - 1500 V955 V - 1500 V
DC Voltage Range MPPT835 V - 1300 V875 V - 1300 V915 V - 1300 V955 V - 1300 V
Number of Power Modules1 independent MPPT
Max. DC Current @40ºC [104ºF]2 x 2500 A
Max. DC Current @50ºC [122ºF]2 x 2313 A
Max. DC Current @55ºC [131ºF]2 x 2220 A
Max. DC Current @60ºC [140ºF]2 x 1110 A
Number of Fused DC Inputs(2)Up to 24 fuse +/- monitored
Energy Production from0.35% Pn approx.
AC CONNECTION
Number of PhasesThree-phase
Nominal AC Power Total @40ºC [104ºF]4095 kVA4299 kVA4504 kVA4709 kVA
Nominal AC Power Total @50ºC [122ºF]3790 kVA3979 kVA4169 kVA4358 kVA
Nominal AC Power Total @55°C [131°F]3637 kVA3819 kVA4001 kVA4183 kVA
Nominal AC Power Total @60°C [140°F]1819 kVA1910 kVA2001 kVA2091 kVA
Max. AC Current @40°C [104°F]3940 Arms
Nominal AC Voltage, LV side600 Vrms630 Vrms660 Vrms690 Vrms
Nominal AC Voltage, MV sideUp to 34.5 kV
Nominal Voltage Allowance Range+/-10%
Frequency Range47.5 - 52.5 / 57 - 63.5 Hz
THD of AC Current< 1% @Sn
Power Factor Range0 (lagging) - 1 - 0 (leading)
PROTECTION DEVICES
DC ConnectionMotorized DC switches (on-load), Overvoltage protection (Type 1 + 2 SPD), Reverse polarity detection,
DC ground fault and insulation detection
AC MV ConnectionProtection switchgear / Fuses Pad mounted version
Over-temperature ProtectionIncluded
Emergency Push ButtonIncluded
COMPONENTS PROTEUS PV STATION
Inverters1 x Proteus PV 41001 x Proteus PV 43001 x Proteus PV 45001 x Proteus PV 4700
Transformer(1)(6)Dy11y11 KNAN
Switchgear(1)(6)0L1V / 1L1V / 2L1V up to 38 kV
Custom Auxiliary Transformer(1)Optional
Others(1)Auxiliary cabinet
COMMUNICATIONS
ControlModbus TCP / IP
MonitoringModbus TCP / IP
WebserverIncluded
OTHER FEATURES
Temperature Range - Operation(1)(2)-20ºC / +60ºC [-4ºF / +140ºF]
Relative Humidity4% - 100% (without condensation)
Maximum Altitude (without derating)(3)2,000 m [6,561 ft]
Dimensions W x H x D (IEC / UL version)(4)11,800 x 2,600 x 2,100 mm / 30 x 8.5 x 8.6 ft
Protection(5)IP54
Cooling SystemLiquid & forced air
OPTIONALS(1)
Low Temperature Kit to up to -30ºC [-22ºF]
Different rating fuses
Enhanced corrosion protection
Motorized MV Switchgear
UPS
Custom Auxiliary Transformer
Seismic Reinforcement

Standards/Directives(5)

  • IEC 62109-1
  • IEC 62109-2
  • IEC 61000-6-2
  • IEEE 1547
  • EN 55011/CISPRºº:2019
  • IEC 62116
  • UL 1741-SB
  • CSA 22.2 No 107.1
  • NFPA 70:2020
  • IEC 62477-1:2022
  • IEEE C57
  • IEC 60076

(1)Consult Gamesa Electric for a specific configuration
(2)With derating from 40ºC [104ºF]
(3)Up to 4,000m [13,123 ft] with derating
(4)UL variant only available for 1-PV Inverter based configuration
(5)Consult Gamesa Electric for more details
(6)UL version: Padmounted Dyn (without external switchgear)

GAMESA ELECTRIC PROTEUS PV STATION2 x Proteus PV 41002 x Proteus PV 43002 x Proteus PV 45002 x Proteus PV 4700
DC CONNECTION
DC Voltage Range835 V - 1500 V875 V - 1500 V915 V - 1500 V955 V - 1500 V
DC Voltage Range MPPT835 V - 1300 V875 V - 1300 V915 V - 1300 V955 V - 1300 V
Number of Power Modules2 independent MPPT
Max. DC Current @40ºC [104ºF]4 x 2500 A
Max. DC Current @50ºC [122ºF]4 x 2313 A
Max. DC Current @55ºC [131ºF]4 x 2220 A
Max. DC Current @60ºC [140ºF]4 x 1110 A
Number of Fused DC Inputs(2)Up to 48 fuse +/- monitored
Energy Production from0,35% Pn approx.
AC CONNECTION
Number of PhasesThree-phase
Nominal AC Power Total @40ºC [104ºF]8190 kVA8598 kVA9008 kVA9418 kVA
Nominal AC Power Total @50ºC [122ºF]7580 kVA7958 kVA8338 kVA8716 kVA
Nominal AC Power Total @55°C [131°F]7274 kVA7638 kVA8002 kVA8366 kVA
Nominal AC Power Total @60°C [140°F]3638 kVA3820 kVA4002 kVA4182 kVA
Maximum AC Current @40°C [104°F]3940 Arms / 2 x 3940 Arms
Nominal AC Voltage, LV side2 x 600 Vrms2 x 630 Vrms2 x 660 Vrms2 x 690 Vrms
Nominal AC Voltage, MV side< 34.5 kV
Nominal Voltage Allowance Range+/-10%
Frequency Range47.5 - 53 / 57 - 63.5 Hz
THD of AC Current< 1% @Sn
Power Factor Range0 (lagging) - 1 - 0 (leading)
PROTECTION DEVICES
DC ConnectionMotorized DC switches (on-load), Overvoltage protection (Type 1 + 2 SPD), Reverse polarity detection,
DC ground fault and insulation detection
AC MV ConnectionProtection switchgear / Fuses Pad mounted version
Over-temperature ProtectionIncluded
Emergency Push ButtonIncluded
COMPONENTS PROTEUS PV STATION
PV Inverters2 x Proteus PV 41002 x Proteus PV 43002 x Proteus PV 45002 x Proteus PV 4700
Transformer(1)Dy11y11 KNAN
Switchgear(1)0L1V / 1L1V / 2L1V up to 38 kV
Custom Auxiliary Transformer(1)Optional
Others(1)Auxiliary cabinet
COMMUNICATIONS
ControlModbus TCP / IP
MonitoringModbus TCP / IP
WebserverIncluded
OTHER FEATURES
Temperature Range - Operation(1)(2)-20ºC / +60ºC [-4ºF / +140ºF]
Relative Humidity4% - 100% (without condensation)
Maximum Altitude (without derating)(3)2,000 m [6,561 ft]
Dimensions W x H x D (IEC / UL version)(4)11,800 x 2,600 x 2,100 mm / 30 x 8.5 x 8.6 ft
Protection(5)IP54
Cooling SystemLiquid & forced air
OPTIONALS
Low Temperature Kit to up to -30ºC [-22ºF]
Different rating fuses
Enhanced corrosion protection
Motorized MV Switchgear
UPS
Custom Auxiliary Transformer
Seismic Reinforcement

Standards/Directives(5)

  • IEC 62109-1
  • IEC 62109-2
  • IEC 61000-6-2
  • IEEE 1547
  • EN 55011/CISPRºº:2019
  • IEC 62116
  • UL 1741-SB
  • CSA 22.2 No 107.1
  • NFPA 70:2020
  • IEC 62477-1:2022
  • IEEE C57
  • IEC 60076

(1)Consult Gamesa Electric for a specific configuration
(2)With derating from 40ºC [104ºF]
(3)Consult P-Q chart
(4)UL variant only available for 1-PV Inverter based configuration
(5)Consult Gamesa Electric for more details

Power Electronics

Motors & Generators

Do you need more information?

Our team is at your disposal