New
Gamesa Electric
Stor 3X series - PCS

High-power
Battery Inverters family

Gamesa Electric Stor 3X series – PCS Battery Inverters

Gamesa Electric
Stor 3X series – PCS Battery Inverters

Maximum efficiency
for utility-scale projects

AEP (Advanced Energy Production)
& UEP (Ultra Energy Production)
configurations

better

High Round Trip Efficiency (RTE)

Market leading efficiency of up to 99.4% (IEC 61683), improving the overall system RTE and LCoS.

Smart liquid/air cooling system that allows critical components to work at temperature level far below their limits, guaranteeing longer product lifespan and lower thermal losses.

AEP and UEP product variant for maximum plant power output.

grid

Grid connection

Four quadrant operation for full active and reactive power support to comply with the most demanding grid codes.

Fast frequency control mode with a response time below 150 ms.

Weak grid and micro-grid configuration with a seamless transition and black start capabilities.

battery

Battery oriented

Safety centered design with instantaneous controls and monitoring both hard-wired and through communication protocols.

Double power module topology for two independent battery connections allowing for much lower DC short-circuit currents and increased system availability.

Battery agnostic design to accommodate different battery technologies, including: li-ion, lead-acid, flow and others.

AEP & UEP configurations

Available to fit any customers' needs

Different product configurations available to optimize performance in demanding environments, IEC and UL certifications, as well as different voltage levels to fit customer's needs.

3X
Gamesa Electric Stor 3X series – PCS Battery Inverters

Coolbrid
cooling system

99.5% Maximum efficiency

Gamesa Electric Stor 3X series – PCS Battery Inverters

Coolbrid Advanced hybrid liquid and air cooling system

Gamesa Electric Stor 3X series – PCS Battery Inverters

Up to 4500 kVA at 660 Vrms

Stor PCS 2550 AEP Stor PCS 2970 AEP Stor PCS 3510 AEP Stor PCS 3830 AEP Stor PCS 4220 AEP
DC Input
DC Minimum Voltage* 620 V 715 V 845 V 925 V 1015 V
DC Maximum Voltage (w/o Derating) < 1300 V
DC Maximum Voltage (with Derating) < 1500 V
Number of Independent Power Modules per PCS 2
Max. DC Current @25°C [77°F] 2 x 2362 A
Max. DC Current @50°C [122°F] 2 x 2100 A
Max. DC Current @55°C [131°F] 2 x 2100 A
Max. DC Current @60°C [140°F] 2 x 1050 A
Number of Fused DC Inputs per Power Module/Total* Up to 3+ & 3- / 6+ & 6-
AC Output
Number of Phases Three-phase w/o neutral point
Nominal AC Power Total @25°C [77°F] 2557 kVA 2973 kVA 3516 kVA 3836 kVA 4220 kVA
Nominal AC Power Total @40°C [104°F] 2272 kVA 2641 kVA 3124 kVA 3408 kVA 3749 kVA
Nominal AC Power Total @55°C [131°F] 2272 kVA 2641 kVA 3124 kVA 3408 kVA 3749 kVA
Nominal AC Power Total @60°C [140°F] 1135 kVA 1320 kVA 1561 kVA 1703 kVA 1873 kVA
Maximum AC Current per Power Module/Total @25°C [77°F] 1846 Arms / 3692 Arms
Nominal AC Voltage* 400 Vrms 465 Vrms 550 Vrms 600 Vrms 660 Vrms
Nominal Voltage Allowance Range* +/- 10%
Frequency Range* 47.5 - 53/57 - 63 Hz
THD of AC Current < 1% @Sn
Power Factor Range 0 (reactive)-1-0 (capacitive)
Performance
Max. Efficiency 98.7% 99.0% 99.2% 99.3% 99.5%
Euro-Efficiency 98.4% 98.7% 98.9% 99.0% 99.2%
Stand-by Power Consumption < 200 W
General Data
Temperature Range - Operation** -20°C / +60°C [-4°F / +140°F]
Maximum Altitude*** < 2000 m [6561 ft] (w/o derating)
Cooling System Liquid & forced air
Relative Humidity 4% – 100% (w/o condensation)
Protection Class IP55 class 1, NEMA3R
Dimensions (W/H/D) 4,325 x 2,250 x 1,022 mm [170.3" x 88.5" x 40.2"]
Weight 3,945 kg [8,697 lb]
AC Protections
AC Side Disconnection & Short-circuit Current Protection Two motorized AC circuit breakers – one per each power module
AC Overvoltage Protection Type 1 + 2 SPD
Anti-islanding Included (SW)
Grid Voltage Fluctuations (LVRT, HVRT)* Included (SW)
Frequency Failure Included (SW)
DC Protections
DC Disconnection Two motorized DC switches (on-load) – one per each power module
DC Short-curcuit Protection DC fast fuses
DC Over-voltage Protection Type 1 + 2 SPD
Reverse Polarity Detection Included
DC Ground Fault and Insulation Detection Included
Other Protections
Over-temperature Protection Included
Emergency Stop Push Button Included
Communications
Control* Modbus TCP/IP (Profinet, CAN upon request)
Monitoring* Modbus TCP/IP
Webserver Included
Optionals Standards/Directives
Low Temperature Kit up to -40 °C [-40°F] IEC 62109-1 IEC 62116 CSA C22.2
DC Input Current Monitoring IEC 62109-2 IEC 61683 UL 62109-1
DC Ground Connection Kit IEC 61000-6-2 IEEE 519 NEC
IEC 61000-6-4 IEC 60529 Rule 21
EN 55011 IEC 61727 Rule 14
IEC 62920 PO12.2 PRC 024
EN 50530 UL 1741-SA

* Consult Gamesa Electric for a specific configuration
** With derating from 25°C / 77ºF
*** Up to 4000 m (13123 ft) with derating as optional
**** Consult Gamesa Electric for other Standards / Directives

Stor PCS 2720 UEP Stor PCS 3170 UEP Stor PCS 3750 UEP Stor PCS 4090 UEP Stor PCS 4500 UEP
DC Input
DC Minimum Voltage* 620 V 715 V 845 V 925 V 1015 V
DC Maximum Voltage (w/o Derating) < 1300 V
DC Maximum Voltage (with Derating) < 1500 V
Number of Independent Power Modules per PCS 2
Max. DC Current @25°C [77°F] 2 x 2500 A
Max. DC Current @50°C [122°F] 2 x 2220 A
Max. DC Current @55°C [131°F] 2 x 2220 A
Max. DC Current @60°C [140°F] 2 x 1110 A
Number of Fused DC Inputs per Power Module/Total* Up to 3+ & 3- / 6+ & 6-
AC Output
Number of Phases Three-phase w/o neutral point
Nominal AC Power Total @25°C [77°F] 2729 kVA 3173 kVA 3753 kVA 4094 kVA 4503 kVA
Nominal AC Power Total @40°C [104°F] 2424 kVA 2818 kVA 3334 kVA 3637 kVA 4000 kVA
Nominal AC Power Total @55°C [131°F] 2424 kVA 2818 kVA 3334 kVA 3637 kVA 4000 kVA
Nominal AC Power Total @60°C [140°F] 1212 kVA 1409 kVA 1667 kVA 1819 kVA 2000 kVA
Maximum AC Current per Power Module/Total @25°C [77°F] 1970 Arms / 3940 Arms
Nominal AC Voltage* 400 Vrms 465 Vrms 550 Vrms 600 Vrms 660 Vrms
Nominal Voltage Allowance Range* +/- 10%
Frequency Range* 47.5 - 53/57 - 63 Hz
THD of AC Current < 1% @Sn
Power Factor Range 0 (reactive)-1-0 (capacitive)
Performance
Max. Efficiency 98.6% 98.8% 99.0% 99.2% 99.4%
Euro-Efficiency 98.3% 98.5% 98.7% 98.9% 99.1%
Stand-by Power Consumption < 200 W
General Data
Temperature Range - Operation** -20°C / +60°C [-4°F / +140°F]
Maximum Altitude*** < 2000 m [6561 ft] (w/o derating)
Cooling System Liquid & forced air
Relative Humidity 4% – 100% (w/o condensation)
Protection Class IP55 class 1, NEMA3R
Dimensions (W/H/D) 4,325 x 2,250 x 1,022 mm [170.3" x 88.5" x 40.2"]
Weight 3,945 kg [8,697 lb]
AC Protections
AC Side Disconnection & Short-circuit Current Protection Two motorized AC circuit breakers – one per each power module
AC Overvoltage Protection Type 1 + 2 SPD
Anti-islanding Included (SW)
Grid Voltage Fluctuations (LVRT, HVRT)* Included (SW)
Frequency Failure Included (SW)
DC Protections
DC Disconnection Two motorized DC switches (on-load) – one per each power module
DC Short-curcuit Protection DC fast fuses
DC Over-voltage Protection Type 1 + 2 SPD
Reverse Polarity Detection Included
DC Ground Fault and Insulation Detection Included
Other Protections
Over-temperature Protection Included
Emergency Stop Push Button Included
Communications
Control* Modbus TCP/IP (Profinet, CAN upon request)
Monitoring* Modbus TCP/IP
Webserver Included
Optionals Standards/Directives
Low Temperature Kit up to -40 °C [-40°F] IEC 62109-1 IEC 62116 CSA C22.2
DC Input Current Monitoring IEC 62109-2 IEC 61683 UL 62109-1
DC Ground Connection Kit IEC 61000-6-2 IEEE 519 NEC
IEC 61000-6-4 IEC 60529 Rule 21
EN 55011 IEC 61727 Rule 14
IEC 62920 PO12.2 PRC 024
EN 50530 UL 1741-SA

* Consult Gamesa Electric for a specific configuration
** With derating from 25°C / 77ºF
*** Up to 4000 m (13123 ft) with derating as optional
**** Consult Gamesa Electric for other Standards / Directives

Do you need more information?

Our team is at your disposal

Contact us