Gamesa Electric PV Station 7500

Gamesa Electric
PV Station 7500

Larger MV solution for LCoE reduction

better

Better LCoE

Compact design that achieves a high power density obtaining overall cost reduction by using less PV station units per project.

Design with best-in-class components that guarentees less probability of failure and therefore less operation cost (materials and workforce).

Market leading inverter efficiency of 99%.

reduction

CAPEX reduction

Less units needed per project, which results in lower equipment cost.

Reduced costs of transportation, offloading and site preparation.

Solution delivered preassembled, configured and tested, reducing on-site labour cost.

link

Plug & Play

Fully assembled and tested MV solution.

Quick installation on field, reducing installation time and costs.

Easy to support and maintain.

Gamesa Electric PV Station 7500

Successfully operating in extreme locations

Gamesa Electric PV Station 7500

Plug & Play

Gamesa Electric PV Station 7500

Advanced liquid+forced air cooling system

PV Station 7500 PV Station 3750
Input (DC)
Number of inverters 2 x Gamesa Electric PV 3750 1 x Gamesa Electric PV 3750
DC Voltage Range 915-1500 V
DC Voltage Range, MPPT 915-1300 V
Maximum DC Voltage 1500 V
Maximum DC Current (25ºC) 4 x 2070 A 2 x 2070 A
Maximum DC Current (50ºC) 4 x 1990 A 2 x 1990 A
Number of DC Ports Up to 48 fuse +/- monitored
Up to 72 fuse + monitored
Up to 24 fuse +/- monitored
Up to 36 fuse + monitored
MPPT 2 1
Output (AC)
AC Output Power @ PF=1, 25ºC 7500 kVA 3750 kVA
AC Output Power @ PF=1, 50ºC 7200 kVA 3600 kVA
Number of Phases Three-phase
Frequency 50/60 Hz
MV Switchgear 0L1V/1L1V/2L1V FS6 isolated up to 36 kV
Transformer Type ONAN (KNAN as optional)
Transformer Connection Group 7.5 MVA Dyn11yn11 3.75 MVA Dyn11
Power Factor -1 to 1
General Data
Dimensions (W/H/D) 11400 x 2600 x 2100 mm
Operation Temperature* -20ºC to 60ºC
Maximum Altitude
(without Derating)
2000 m
Degree of Protection IP54, NEMA 3R
Corrosion Protection C4H
Cooling Water & forced air
Features
Reactive Control YES (through external and internal configuration)
LVRT Capability YES, including reactive injection
STATCOM Mode for Night Compensation YES
HVRT Capability YES
Communication Protocol Modbus TCP-IP
Webserver YES

* With derating from 25ºC

Optionals
-40ºC Low Temperature Kit
UPS for Supplying Trackers
Motorized MV Switchgear
High Corrosion Protection Kit
Seismic Reinforcement

Do you need more information?

Our team is at your disposal

Contact us