New
Gamesa Electric PV
3X series - PV Stations

High-power
PV Inverter family

Maximum power
with large flexibility
for best LCoE

Gamesa Electric PV 3X series PV Stations

Gamesa Electric
PV 3X series
PV Stations

Plug & Play MV Solutions

better

Better LCoE

Compact design that achieves a high power density obtaining overall cost reduction by using less PV station units per project.

Design with best-in-class components that guarentees less probability of failure and therefore less operation cost (materials and workforce).

Market leading inverter efficiency of 99.52%.

reduction

CAPEX reduction

Less units needed per project, which results in lower equipment cost.

Reduced costs of transportation, offloading and site preparation.

Solution delivered preassembled, configured and tested, reducing on-site labour cost.

puzzle

Flexibility

Wide range of configurations with outputs from 3400 to 7850 kVA, HTD version for desert environments and IEC & UL certifications.

Bidirectional inverter that allows PV Station to be configured as part of a Battery Energy Storage System (BESS) in DC and AC coupling topologies.

Customization at PV station subsystems, such as MV transformer, auxiliaries’ system and DC input configuration, according to customer necessities.

link

Plug & play

Fully assembled and tested MV solution.

Quick installation on field, reducing installation time and costs.

Easy to support and mantain.

2 inverters

IEC version
2 Inverters

1 inverters

IEC version
1 Inverter

UL version

UL version
1 Inverter

Different Configurations

IEC & UL versions

The Gamesa Electric PV 3X series
PV Stations combine maximum power
with large flexibility for best LCoE

PVS 3400(1) PVS 3600(1) PVS 3750(1) PVS 3900(1)
Number of Inverters(1) 1 x PV 3400 1 x PV 3600 1 x PV 3750 1 x PV 3900
DC Input
Ratio DC/AC 160% (up to 200% upon request)
Max. DC Current @25ºC [77ºF] 2 x 2100 A
Max. DC Current @50ºC [122ºF] (STD/HTD) 2 x 1990 A / 2 x 2100 A
Max. DC Current @55ºC [131ºF] (STD/HTD) 2 x 995 A / 2 x 2100 A
Max. DC Current @60ºC [140ºF] (HTD) 2 x 1050 A
Maximum Short-circuit Current, Isc PV 6400 A (up to 8000 A upon request)
DC Voltage Range 835 - 1500 V 875 - 1500 V 915 - 1500 V 955 - 1500 V
DC Voltage Range MPPT 835 - 1300 V 875 - 1300 V 915 - 1300 V 955 - 1300 V
Nr of DC Ports Max 24 fuse +/- monitored
Max 36 fuse + monitored
MPPT 1
AC Output
Nominal AC Power @25ºC [77ºF] 3409 kVA 3579 kVA 3750 kVA 3920 kVA
Nominal AC Power @50ºC [122ºF] (STD/HTD) 3300 / 3409 kVA 3450 / 3579 kVA 3600 / 3750 kVA 3750 / 3920 kVA
Nominal AC Power @55ºC [131ºF] (STD/HTD) 1650 / 3409 kVA 1725 / 3579 kVA 1800 / 3750 kVA 1875 / 3920 kVA
Nominal AC Power @60ºC [140ºF] (STD/HTD) 0 / 1704 kVA 0 / 1789 kVA 0 / 1875 kVA 0 / 1959 kVA
Nominal AC Voltage 13.8 - 34.5 kV rms
AC Power Frequency 50 / 60 Hz
Reactive Power Range Any
Protective Devices
DC Input Fuse and motorized load disconnector
AC Input Circuit breaker
Overvoltage Protections DC Type 1 + 2 SPD
Components PV Station
Inverter(1) 1 x PV 3400 1 x PV 3600 1 x PV 3750 1 x PV 3900
Transformer* 3.42 MVA Dyn 3.60 MVA Dyn 3.75 MVA Dyn 3.93 MVA Dyn
Switchgear* 0L1 V up to 36 kV
Custom Auxiliary Transformer Optional
Others Auxilliary cabinet
Communications
Control Modbus TCP / IP (Profinet, CAN upon request)
Monitoring Modbus TCP / IP
Other Features
LVRT Yes
HVRT Yes
Working Ambient Temperature * -20°C / +60°C (-4ºF / +140ºF). Option -40ºC (-40ºF)
Relative Humidity 100% (without condensation)
Max. Altitude (whithout derating) ** 2000 m (6561ft)
Dimensions W x H x D (IEC / UL version) 11800 x 2600 x 2100 mm / 30 x 8.5 x 10 ft
Weight (IEC / UL version) 19000 Kg / 44000 lbs
Protection IP54, NEMA3R
Cooling Liquid & forced air
Main Standards Optionals
IEC 62109 -40°C Low Temperature Kit
UL 1741-SA UPS for Supplying Trackers
UL 62109 Motorized MV Switchgear
NEC 2017 High Corrosion Protection Kit
Seismic Reinforcement

(1) With different configurations: STD (standard version for IEC markets), U (UL certified) variant and HTD (High Temperature & Dust) variant
* UL version: Padmounted Dyn (without external switchgear)
** With derating from 25ºC/77ºF in STD version and from 55º/131ºF in HTD version
*** Up to 4000m (13123ft) with derating, as optional

PVS 6850(1) PVS 7200(1) PVS 7500(1) PVS 7850(1)
Number of Inverters(1) 2 x PV 3400 2 x PV 3600 2 x PV 3750 2 x PV 3900
DC Input
Ratio DC/AC 160% (up to 200% upon request)
Max. DC Current @25ºC [77ºF] 4 x 2100 A
Max. DC Current @50ºC [122ºF] (STD/HTD) 4 x 1990 A / 4 x 2100 A
Max. DC Current @55ºC [131ºF] (STD/HTD) 4 x 995 A / 4 x 2100 A
Max. DC Current @60ºC [140ºF] (HTD) 4 x 1050 A
Maximum Short-circuit Current, Isc PV 6400 A (up to 8000 A upon request)
DC Voltage Range 835 - 1500 V 875 - 1500 V 915 - 1500 V 955 - 1500 V
DC Voltage Range MPPT 835 - 1300 V 875 - 1300 V 915 - 1300 V 955 - 1300 V
Nr of DC Ports Max 2 x 24 fuse +/- monitored
Max 2 x 36 fuse + monitored
MPPT 2
AC Output
Nominal AC Power @25ºC [77ºF] 6818 kVA 7158 kVA 7500 kVA 7840 kVA
Nominal AC Power @50ºC [122ºF] (STD/HTD) 6600 / 6818 kVA 6900 / 7158 kVA 7200 / 7500 kVA 7500 / 7840 kVA
Nominal AC Power @55ºC [131ºF] (STD/HTD) 3300 / 6818 kVA 3450 / 7158 kVA 3600 / 7500 kVA 3750 / 7840 kVA
Nominal AC Power @60ºC [140ºF] (STD/HTD) 0 / 3409 kVA 0 / 3579 kVA 0 / 3750 kVA 0 / 3920 kVA
Nominal AC Voltage 13.8 - 34.5 kV rms
AC Power Frequency 50 / 60 Hz
Reactive Power Range Any
Protective Devices
DC Input Fuse and motorized load disconnector
AC Input Circuit breaker
Overvoltage Protections DC Type 1 + 2 SPD
Components PV Station
Inverter(1) 2 x PV 3400 2 x PV 3600 2 x PV 3750 2 x PV 3900
Transformer* 6.84 MVA Dyn 7.18 MVA Dyn 7.50 MVA Dyn 7.86 MVA Dyn
Switchgear* 0L1 V up to 36 kV
Custom Auxiliary Transformer Optional
Others Auxilliary cabinet
Communications
Control Modbus TCP / IP (Profinet, CAN upon request)
Monitoring Modbus TCP / IP
Other Features
LVRT Yes
HVRT Yes
Working Ambient Temperature * -20°C / +60°C (-4ºF / +140ºF). Option -40ºC (-40ºF)
Relative Humidity 100% (without condensation)
Max. Altitude (whithout derating) ** 2000 m (6561ft)
Dimensions W x H x D (IEC / UL version) 11800 x 2600 x 2100 mm / 38 x 8.5 x 10 ft
Weight (IEC / UL version) 26500 Kg / 75000 lbs
Protection IP54, NEMA3R
Cooling Liquid & forced air
Main Standards Optionals
IEC 62109 -40°C Low Temperature Kit
UL 1741-SA UPS for Supplying Trackers
UL 62109 Motorized MV Switchgear
NEC 2017 High Corrosion Protection Kit
Seismic Reinforcement

(1) With different configurations: STD (standard version for IEC markets), U (UL certified) variant and HTD (High Temperature & Dust) variant
* UL version: Padmounted Dyn (without external switchgear)
** With derating from 25ºC/77ºF in STD version and from 55º/131ºF in HTD version
*** Up to 4000m (13123ft) with derating, as optional