New
Gamesa Electric PV
2X series - PV Stations

High-power
PV Inverter family

Plug & Play MV Solutions
for large-scale 1500 V
power plants

Gamesa Electric PV 2X series PV Stations

Gamesa Electric
PV 2X series
PV Stations

Plug & Play MV Solutions

compact

Performance at harsh environmental conditions

Double physical protection (metallic container and inverter enclosure) against dust and sand.

Liquid cooling allows to reduce air flow exchange necessities, avoiding dust and sand entrance in critical components.

Any O&M task can be performed within the building (metallic container), avoiding climatic conditions exposure.

reliability

Reliability

Up to 5.2 MW solution based on 2 field-proven Gamesa Electric PV 2X series inverters.

More yield in challenging sites: operating up to 50ºC and 2000 m without derating.

Best support available from our service organization.

puzzle

Flexibility

Wide range of configurations with outputs from 2250 kVA to 5200 kVA.

Bidirectional inverter that allows PV Station to be configured as part of a Battery Energy Storage System (BESS).

Customization at PV station subsystems, such as MV transformer, auxiliaries’ system and DC input configuration, according to customer necessities.

link

Plug & play

Fully assembled and tested MV solution.

Quick installation on field, reducing installation time and costs.

Easy to support and mantain.

Different Configurations

The Gamesa Electric PV 2X series
PV Stations combine maximum power
with large flexibility for best LCoE

Concrete
Solution

Container
Standard

Container
Plus

1 Inverter

Concrete Solution

Gamesa Electric PV 2X Station

Container Standard

Gamesa Electric PV 2X Station

Container Plus

Gamesa Electric PV 2X Station

2 Inverters

Concrete Solution

Gamesa Electric PV 2X Station

Container Standard

Gamesa Electric PV 2X Station

Container Plus

Gamesa Electric PV 2X Station
PVS 2350 PVS 2475 PVS 2600 PVS 2250 PVS 2400 PVS 2500
DC Input
Ratio DC/AC 127% (up to 177% upon request) 129% (up to 179% upon request)
Max. DC Current @25ºC [77ºF] 2 x 1468 A 2 x 1460 A
Max. DC Current @40ºC [104ºF] 2 x 1440 A 2 x 1440 A
Max. DC Current @50ºC [122ºF] (STD/HTD) 2 x 1412 A 2 x 1400 A
DC Voltage Range 820 - 1500 V 860 - 1500 V 900 - 1500 V 820 - 1500 V 860 - 1500 V 900 - 1500 V
DC Voltage Range MPPT 820 - 1300 V 860 - 1300 V 900 - 1300 V 820 - 1300 V 860 - 1300 V 900 - 1300 V
Nr of DC Ports max 16 fuse +/-
max 18 fuse +
(up to max 24 fuse +/- monitored upon request)
MPPT 1
AC Output
Nominal AC Power @25ºC [77ºF] 2363 kVA 2480 kVA 2600 kVA 2270 kVA 2386 kVA 2500 kVA
Nominal AC Power @40ºC [104ºF] 2315 kVA 2430 kVA 2550 kVA 2136 kVA 2240 kVA 2350 kVA
Nominal AC Power @50ºC [122ºF] 2273 kVA 2385 kVA 2500 kVA 2045 kVA 2147 kVA 2250 kVA
Nominal AC Voltage Up to 34.5 kV
AC Power Frequency 50 / 60 Hz
Reactive Power Range Any
Protective Devices
DC Input Fuse and motorized load switch
AC Input Circuit breaker (Motorized as an option)
Overvoltage Protections DC Type 1 + 2 SPD
Components PV Station
Inverter 1 x PV 2350 1 x PV 2475 1 x PV 2600 1 x PV 2250 1 x PV 2400 1 x PV 2500
Transformer 2.36 MVA Dyn 2.48 MVA Dyn 2.6 MVA Dyn 2.27 MVA Dyn 2.39 MVA Dyn 2.5 MVA Dyn
Switchgear 0L1V / 1L1V / 2L1V up to 36 kV
Custom auxiliary transformer Optional
Others Auxiliary cabinet
Communications
Control Modbus TCP / IP (Other upon request)
Monitoring Modbus TCP / IP
Other Features
LVRT Yes
HVRT Yes
Working Ambient Temperature * -20°C / +60°C (-4ºF / +140ºF)
Max. Altitude (whithout derating) ** 2000 m (6561 ft)
Dimensions container
(width x height x depth)
6058 x 2438 x 2896 mm (20 x 8 x 9.5 ft)
Dimensions concrete building
(width x height x depth)
7500 x 2500 x 3240 mm (24.6 x 8.2 x 10.6 ft)
Weight container 12500 kg (27558 lb)
Weight concrete building 30000 kg concrete building + 5000 kg transformer (66139 lb + 11023 lb)
Protection IP53 (inverter and switchgear compartment) – IP54 as optional / IP10 (transformer compartment)***
Cooling Liquid & forced air
Main Standards Optionals
IEC 62109-1 IEC 62109-2 Container Plus(1) AC & DC cables IP67 protection
IEC 61000-6-2 EN 55011:2016 Low temperature kit UPS
IEC 62116 IEC 61683 C5 corrosion painting upgrade
IEEE 519 IEEE 1547
USA: UL 1741-SA UL62109
C22.2 No 107.1-01:2001 AUS: AS 4777.2:2015
INDIA: CEA 6th February, 2019 IEC TS 62910:2015

* With derating from 25ºC / 77ºF
** Up to 4000 m (13123 ft) with derating as optional
*** Only applicable for container solution
(1) Consult Gamesa Electric for details

PVS 4700 PVS 4950 PVS 5200 PVS 4500 PVS 4800 PVS 5000
DC Input
Ratio DC/AC 127% (up to 177% upon request) 129% (up to 179% upon request)
Max. DC Current @25ºC [77ºF] 4 x 1468 A 4 x 1460 A
Max. DC Current @40ºC [104ºF] 4 x 1440 A 4 x 1440 A
Max. DC Current @50ºC [122ºF] (STD/HTD) 4 x 1412 A 4 x 1400 A
DC Voltage Range 820 - 1500 V 860 - 1500 V 900 - 1500 V 820 - 1500 V 860 - 1500 V 900 - 1500 V
DC Voltage Range MPPT 820 - 1300 V 860 - 1300 V 900 - 1300 V 820 - 1300 V 860 - 1300 V 900 - 1300 V
Nr of DC Ports max 16 fuse +/-
max 18 fuse +
(up to max 24 fuse +/- monitored upon request)
MPPT 1
AC Output
Nominal AC Power @25ºC [77ºF] 4726 kVA 4960 kVA 5200 kVA 4540 kVA 4772 kVA 5000 kVA
Nominal AC Power @40ºC [104ºF] 4630 kVA 4860 kVA 5100 kVA 4272 kVA 4480 kVA 4700 kVA
Nominal AC Power @50ºC [122ºF] 4726 kVA 4770 kVA 5000 kVA 4090 kVA 4294 kVA 4500 kVA
Nominal AC Voltage Up to 34.5 kV
AC Power Frequency 50 / 60 Hz
Reactive Power Range Any
Protective Devices
DC Input Fuse and motorized load switch
AC Input Circuit breaker (Motorized as an option)
Overvoltage Protections DC Type 1 + 2 SPD
Components PV Station
Inverter 2 x PV 2350 2 x PV 2475 2 x PV 2600 2 x PV 2250 2 x PV 2400 2 x PV 2500
Transformer 4.76 MVA Dynyn 4.96 MVA Dynyn 5.2 MVA Dynyn 4.54 MVA Dynyn 4.77 MVA Dynyn 5 MVA Dynyn
Switchgear 0L1V / 1L1V / 2L1V up to 36 kV
Custom auxiliary transformer Optional
Others Auxiliary cabinet
Communications
Control Modbus TCP / IP (Other upon request)
Monitoring Modbus TCP / IP
Other Features
LVRT Yes
HVRT Yes
Working Ambient Temperature * -20°C / +60°C (-4ºF / +140ºF)
Max. Altitude (whithout derating) ** 2000 m (6561 ft)
Dimensions container
(width x height x depth)
12192 x 2438 x 2896 mm (40 x 8 x 9.5 ft)
Dimensions concrete building
(width x height x depth)
7500 x 2500 x 3240 mm (24.6 x 8.2 x 10.6 ft)
Weight container 21000 kg (46297 lb)
Weight concrete building 32500 kg concrete building + 10000 kg transformer (71650 lb + 22046 lb)
Protection IP53 (inverter and switchgear compartment) – IP54 as optional / IP10 (transformer compartment)***
Cooling Liquid & forced air
Main Standards Optionals
IEC 62109-1 IEC 62109-2 Container Plus(1) AC & DC cables IP67 protection
IEC 61000-6-2 EN 55011:2016 Low temperature kit UPS
IEC 62116 IEC 61683 C5 corrosion painting upgrade
IEEE 519 IEEE 1547
USA: UL 1741-SA UL62109
C22.2 No 107.1-01:2001 AUS: AS 4777.2:2015
INDIA: CEA 6th February, 2019 IEC TS 62910:2015

* With derating from 25ºC / 77ºF
** Up to 4000 m (13123 ft) with derating as optional
*** Only applicable for container solution
(1) Consult Gamesa Electric for details

Do you need more information?

Our team is at your disposal

Contact us