New
Gamesa Electric
Proteus PV
Stations

High-power
PV Inverter family

Maximum power
with large flexibility
for best LCoE

Gamesa Electric Proteus PV Stations

Gamesa Electric
Proteus PV Stations

Plug & Play MV Solutions

better

Better LCoE

Compact design that achieves a high power density obtaining overall cost reduction by using less PV station units per project.

Design with best-in-class components that guarantees less probability of failure and therefore less operation cost (materials and workforce).

Market leading inverter efficiency of 99.45%.

reduction

CAPEX reduction

Less units needed per project, which results in lower equipment cost.

Reduced costs of transportation, offloading and site preparation.

Solution delivered preassembled, configured and tested, reducing on-site labour cost.

puzzle

Flexibility

Wide range of configurations with outputs from 3800 to 9400 kVA and IEC & UL certifications.

Bidirectional inverter that allows PV Station to be configured as part of a Battery Energy Storage System (BESS) in DC and AC coupling topologies.

Customization at PV station subsystems, such as MV transformer, auxiliaries’ system and DC input configuration, according to customer necessities.

link

Plug & play

Fully assembled and tested MV solution.

Quick installation on field, reducing installation time and costs.

Easy to support and mantain.

2 inverters

IEC version
2 Inverters

1 inverters

IEC version
1 Inverter

UL version

UL version
1 Inverter

Configurations

Available to fit any customers' needs

The Gamesa Electric Proteus PV Stations
combine maximum power with
large flexibility for best LCoE

Gamesa Electric Proteus PV Station
1 x Proteus PV 4100 1 x Proteus PV 4300 1 x Proteus PV 4500 1 x Proteus PV 4700
DC Connection
DC Voltage Range(1) 835 V - 1500 V 875 V - 1500 V 915 V - 1500 V 955 V - 1500 V
DC Voltage Range MPPT((1) 835 V - 1300 V 875 V - 1300 V 915 V - 1300 V 955 V - 1300 V
Number of Power Modules 2, not galvanically isolated, 1 MPPT
Max. DC Current @40ºC [104ºF] 2 x 2500 A
Max. DC Current @50ºC [122ºF] 2 x 2313 A
Max. DC Current @55ºC [131ºF] 2 x 2220 A
Max. DC Current @60ºC [140ºF] 2 x 1110 A
Number of DC Ports(1) max 24 fuse +/- monitored
max 36 fuse + monitored
AC Connection
Number of Phases Three-phase
Nominal AC Power Total @40ºC [104ºF] 4095 kVA 4299 kVA 4504 kVA 4709 kVA
Nominal AC Power Total @50ºC [122ºF] 3790 kVA 3979 kVA 4169 kVA 4358 kVA
Nominal AC Power Total @55°C [131°F] 3637 kVA 3819 kVA 4001 kVA 4183 kVA
Nominal AC Power Total @60°C [140°F] 1819 kVA 1910 kVA 2001 kVA 2091 kVA
Maximum AC Current @40°C [104°F] 3940 Arms
Nominal AC Voltage, LV side(1) 600 Vrms 630 Vrms 660 Vrms 690 Vrms
Nominal AC Voltage, MV side(1) < 34.5kV
Nominal Voltage Allowance Range(1) +/-10%
Frequency Range(1) 50/60 Hz (+6% / -7%)
THD of AC Current < 1% @Sn
Power Factor Range(3) 0 (lagging) - 1 - 0 (leading)
Protection Devices
DC Connection Motorized disconnectors, Overvoltage protection (Type 1 + 2 SPD), reverse polarity detection, DC ground fault and insulation detection
AC Connection Motorized AC circuit breakers, Overvoltage protection (Type 1 + 2 SPD), Anti-islanding, Voltage failure, Frequency failure
Over-temperature Protection Included
Emergency Push Button Included
Components Proteus PV Station
PV Inverters 1 x Proteus PV 4100 1 x Proteus PV 4300 1 x Proteus PV 4500 1 x Proteus PV 4700
Transformer(1)(6) Dyn KNAN / ONAN
Switchgear(1)(6) 0L1V / 1L1V / 2L1V up to 36 kV
Custom Auxiliary Transformer(2) Optional
Others(1) Auxiliary cabinet
Communications
Control(1) Modbus TCP / IP
Monitoring(1) Modbus TCP / IP
Webserver Included
Other Features
LVRT Yes
HVRT Yes
Temperature Range - Operation(2) -20ºC / +60ºC [-4ºF / +140ºF], Option -30ºC [-22ºF]
Relative Humidity 4% - 100% (without condensation)
Maximum Altitude (without derating)(3) 2,000 m [6561 ft]
Dimensions W x H x D (IEC / UL version)(4) 11800 x 2600 x 2100 mm / 30 x 8,5 x 8,6 ft
Protection IP54
Cooling System Liquid & forced air
Optionals Standards/Directives(5)
Low Temperature Kit to up to -30ºC [-22ºF] IEC 62109-1 IEC 60529
Enhanced corrosion protection IEC 62109-2 IEC 61727
Motorized MV Switchgear IEC 61000-6-2/4 NTS 631 v1.1 SENP, v2.1 SEPE
UPS IEEE 1547 UL 1741-SA
Custom Auxiliary Transformer EN 55011 CSA C22.2
Seismic Reinforcement IEC 62920 NEC 2020
EN 50530 CEA 2007
IEC 62116 Rule 14, Rule 21
IEC 61683 PRC 024
IEEE 519 UL 62109-1

(1)Consult Gamesa Electric for a specific configuration
(2)With derating from 40ºC [104ºF]
(3)Up to 4,000m [13,123 ft] with derating as optional
(4)UL variant only available for 1-PV Inverter based configuration
(5)Consult Gamesa Electric for other Standards/Directives
(6)UL version: Padmounted Dyn (without external switchgear)

Gamesa Electric Proteus PV Station
2 x Proteus PV 4100 2 x Proteus PV 4300 2 x Proteus PV 4500 2 x Proteus PV 4700
DC Connection
DC Voltage Range(1) 835 V - 1500 V 875 V - 1500 V 915 V - 1500 V 955 V - 1500 V
DC Voltage Range MPPT((1) 835 V - 1300 V 875 V - 1300 V 915 V - 1300 V 955 V - 1300 V
Number of Power Modules 4, 2 independent MPPT
Max. DC Current @40ºC [104ºF] 4 x 2500 A
Max. DC Current @50ºC [122ºF] 4 x 2313 A
Max. DC Current @55ºC [131ºF] 4 x 2220 A
Max. DC Current @60ºC [140ºF] 4 x 1110 A
Number of DC Ports(1) max 48 fuse +/- monitored
max 72 fuse + monitored
AC Connection
Number of Phases Three-phase
Nominal AC Power Total @40ºC [104ºF] 8190 kVA 8598 kVA 9008 kVA 9418 kVA
Nominal AC Power Total @50ºC [122ºF] 7580 kVA 7958 kVA 8338 kVA 8716 kVA
Nominal AC Power Total @55°C [131°F] 7274 kVA 7638 kVA 8002 kVA 8366 kVA
Nominal AC Power Total @60°C [140°F] 3638 kVA 3820 kVA 4002 kVA 4182 kVA
Maximum AC Current @40°C [104°F] 3940 Arms / 2 x 3940 Arms
Nominal AC Voltage, LV side(1) 2 x 600 Vrms 2 x 630 Vrms 2 x 660 Vrms 2 x 690 Vrms
Nominal AC Voltage, MV side(1) < 34.5kV
Nominal Voltage Allowance Range(1) +/-10%
Frequency Range(1) 47.5 - 53 / 57 - 63 Hz
THD of AC Current < 1% @Sn
Power Factor Range 0 (reactive)-1-0 (capacitive)
Protection Devices
DC Connection Motorized disconnectors, Overvoltage protection (Type 1 + 2 SPD), reverse polarity detection, DC ground fault and insulation detection
AC Connection Motorized AC circuit breakers, Overvoltage protection (Type 1 + 2 SPD), Anti-islanding, Voltage failure, Frequency failure
Over-temperature Protection Included
Emergency Push Button Included
Components Proteus PV Station
PV Inverters 2 x Proteus PV 4100 2 x Proteus PV 4300 2 x Proteus PV 4500 2 x Proteus PV 4700
Transformer(1)(6) Dyn KNAN / ONAN
Switchgear(1)(6) 0L1V / 1L1V / 2L1V up to 36 kV
Custom Auxiliary Transformer(2) Optional
Others(1) Auxiliary cabinet
Communications
Control(1) Modbus TCP / IP
Monitoring(1) Modbus TCP / IP
Webserver Included
Other Features
LVRT Yes
HVRT Yes
Temperature Range - Operation(2) -20ºC / +60ºC [-4ºF / +140ºF], Option -30ºC [-22ºF]
Relative Humidity 4% - 100% (without condensation)
Maximum Altitude (without derating)(3) 2,000 m [6561 ft]
Dimensions W x H x D (IEC / UL version)(4) 11800 x 2600 x 2100 mm / 30 x 8,5 x 8,6 ft
Protection IP54
Cooling System Liquid & forced air
Optionals Standards/Directives(5)
Low Temperature Kit to up to -30ºC [-22ºF] IEC 62109-1 IEC 60529
Enhanced corrosion protection IEC 62109-2 IEC 61727
Motorized MV Switchgear IEC 61000-6-2/4 NTS 631 v1.1 SENP, v2.1 SEPE
UPS IEEE 1547 UL 1741-SA
Custom Auxiliary Transformer EN 55011 CSA C22.2
Seismic Reinforcement IEC 62920 NEC 2020
EN 50530 CEA 2007
IEC 62116 Rule 14, Rule 21
IEC 61683 PRC 024
IEEE 519 UL 62109-1

(1)Consult Gamesa Electric for a specific configuration
(2)With derating from 40ºC [104ºF]
(3)Up to 4,000m [13,123 ft] with derating as optional
(4)UL variant only available for 1-PV Inverter based configuration
(5)Consult Gamesa Electric for other Standards/Directives
(6)UL version: Padmounted Dyn (without external switchgear)

Do you need more information?

Our team is at your disposal

Contact us